College Physics ›› 2018, Vol. 37 ›› Issue (11): 16-20.doi: 10.16854 /j.cnki.1000-0712.170606
Previous Articles Next Articles
SUN Dian-ping,ZHAO Qiang,GUO Chao-xiu
Received:
Revised:
Online:
Published:
Abstract: In this paper,both the current and the voltage in a transformer are measured by digital oscilloscope. The nonlinear relation between the current harmonic and the voltage is discussed via harmonic analysis,thereinto,the amplitude of three harmonic currents increase rapidly with the increase of the voltage,which is approximately proportional to the voltage to the third power,and the amplitude of the even harmonic current does not significant increase with the voltage. The experimental results are consistent with the theoretical analysis. In addition,three harmonic signals are obtained through different connection of winding in the three-phase transformer,and rule of the three times harmonic wave of the current changing with the voltage is studied.
Key words: three-phase transformer, magnetization curve, three times harmonic wave, circulating current
SUN Dian-ping,ZHAO Qiang,GUO Chao-xiu. Study of analysis and acquisition method of nonlinear harmonic in three-phase transformer [J].College Physics, 2018, 37(11): 16-20.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://dxwl.bnu.edu.cn/EN/10.16854 /j.cnki.1000-0712.170606
https://dxwl.bnu.edu.cn/EN/Y2018/V37/I11/16
Cited