College Physics ›› 2021, Vol. 40 ›› Issue (8): 77-.doi: 10.16854 / j.cnki.1000-0712.210062
Previous Articles Next Articles
SHI Yi-han,LUO Hai-jun,ZHANG Dong
Received:
Revised:
Online:
Published:
Abstract:
The refractive index is an important optical parameter of the medium,and the
measurement of the refractive index is an important part of the optical experiment. In
this experiment,a biprism and a flat glass are used as a container for liquid,a lateral
transmission device is added to the Michelson interferometer to control the movement of the
double air wedge,so an experimental device for measuring liquid refractive index has
been de- signed. This experimental method avoids complicated component processing. It is easy to
operate and has more ac-curate measurement results.
Key words: liquid refractive index, double air wedge, Michelson interferometer
SHI Yi-han, LUO Hai-jun, ZHANG Dong. Measurement of liquid refractive index based on Michelson interferometer and double air wedge [J].College Physics, 2021, 40(8): 77-.