Research on damped vibration with differential capacitance sensor

Expand
  • 1. State Key Laboratory of Precision Spectroscopy,East China Normal University,Shanghai 200062,China; 2. School of Physics and Materials Science,East China Normal University,Shanghai 200062,China

Received date: 2018-10-18

  Revised date: 2018-11-21

  Online published: 2019-08-27

Abstract

The displacement of a test bench is measured by using a sensor with differential variable area and a digital oscilloscope. The better fitting degree is obtained and the damping factor,vibration frequency and other parameters are calculated from the data fitting with the damped vibration equation,which are also compared with the parameters obtained from the fitting data of the amplitude-time curve.

Cite this article

SUN Dian-ping, GUO Chao-xiu, CHAI Zhi-fang, ZHAO Zhen-jie . Research on damped vibration with differential capacitance sensor[J]. College Physics, 2019 , 38(7) : 36 . DOI: 10.16854 /j.cnki.1000-0712.180568

Outlines

/