Thermal effects onsurface tension: a modular optimization approach in pull-off measurement system

Expand
  • Department of Physics, Hubei University, Wuhan, Hubei 430062, China

Received date: 2025-03-07

  Revised date: 2025-05-29

  Online published: 2026-04-22

Abstract

This study addresses the problem of significant errors in measuring liquid surface tension coefficients using the traditional pull-off method. The improved apparatus retains the pull-off methods advantages—such as simple operation and a straightforward structure—and innovatively incorporates a horizontal adjustment module, a peristaltic pump system, and a thermostatic water bath. Experimental results show that the improved device enhances measurement precision by reducing the relative error to 0.5%. This advancement provides a more accurate and reliable approach for measuring liquid surface tension coefficients in general physics experimental teaching, which is crucial for improving the quality of experimental education.



Cite this article

XU Zhengyu, CHEN Xin, YANG Chen, XING Rui, WANG Shuzhuo, LIU Xiang, PENG Xiaoniu . Thermal effects onsurface tension: a modular optimization approach in pull-off measurement system[J]. College Physics, 2026 , 45(1) : 92 . DOI: 10.16854/j.cnki.1000-0712.250165