大学物理 ›› 2025, Vol. 44 ›› Issue (7): 113-.doi: 10.16854/j.cnki.1000-0712.240175

• 大学生园地 • 上一篇    

基于迈克耳孙干涉原理的测温方法

陈俣轩,辛祺,王启栋,段雪松,孔祥明,叶文江   

  1. 1. 河北工业大学 亚利桑那工业学院,天津300401;2. 河北工业大学 理学院,天津300401
  • 收稿日期:2024-04-11 修回日期:2024-10-15 出版日期:2025-09-01 发布日期:2025-09-18
  • 通讯作者: 叶文江,E-mail: wenjiang_ye@hebut.edu.cn
  • 作者简介:陈俣轩,男,汉族,安徽省太和县,河北工业大学,本科,材料物理专业.
  • 基金资助:
    中国高等教育学会专项课题(21LKYB05)、河北省高等教育教学改革研究与实践项目(2017GJJG018)、河北工业大学教育教学改革研究项目(202401028、201802003)和河北工业大学亚利桑那工业学院教育教学改革研究项目(YGJG20240012).


Temperature measurement method based on michelson interference principle

CHEN Yuxuan1, XIN Qi1, WANG Qidong1, DUAN Xuesong2, #br# KONG Xiangming2, YE Wenjiang2   

  1. 1. Hebei University of Technology, Arizona College of Technology, Tianjin 300401, China; 
    2. Hebei University of Technology, School of Sciences, Tianjin 300401, China

  • Received:2024-04-11 Revised:2024-10-15 Online:2025-09-01 Published:2025-09-18

摘要: 温度是表征物体宏观物理性质变化的重要参数之一,精确确定物体温度在物理教学和研究中起着重要作用.迈克耳孙干涉光路是一种常用的光路,有着搭建简单、精度较高的特点.本文提出了一种基于迈克耳孙干涉原理的测温方法,其机理是温度变化引起液体折射率及穿过液体的光程发生变化,从而导致干涉条纹的改变.通过对钟表油、去离子水、无水乙醇、丙三醇、调和油五种液体进行实验测量并对实验数据进行线性拟合,得到了干涉条纹移动数量与温度变化量存在着线性关系.该测温方法优点:线性拟合关系较好,相关系数R2值均大于0.999;可适配的测温为30~80℃,且随介质的不断扩展,此范围可继续扩大;精度较高,不同温度范围下测量相对误差在4%左右;能够准确反映温度变化的实时值.此研究有助于学生对温度定标的理解,拓展学生对温度测量方法的认知.


关键词: 迈克耳孙干涉光路, 折射率, 温度, 测温仪器

Abstract: Temperature is one of the important parameters to characterize the change of macroscopic physical properties of objects. The precise determination of object temperature plays an important role in physics teaching and research. Michelson interference optical path is a common optical path, which has the characteristics of simple construction and high precision. In this paper, a temperature measurement method based on Michelson interference principle is proposed. The mechanism is that the change of temperature causes the change of refractive index and light path through the liquid, which leads to the change of interference fringe. By measuring five kinds of liquids such as clock oil, deionized water, anhydrous ethanol, glycerol and blended oil and linear fitting of experimental data, it is found that there is a linear relationship between the number of interference fringes moving and the change of temperature. The advantages of this method are as follows: the linear fitting relationship is good, and the correlation coefficient R2 values are greater than 0.999; the temperature can be adapted to 30 ~80 °C, and with the continuous expansion of the medium, this range can continue to expand; the relative error is about 4% under different temperature range. It can accurately reflect the real time value of temperature change. This study will help students understand temperature calibration and expand their knowledge of temperature measurement methods.


Key words: Michelson Interference, refractive index, temperature, temperature measuring instrument