›› 2011, Vol. 30 ›› Issue (10): 57-57.

• 著者文摘 • Previous Articles     Next Articles

Measuring the thermal expansion coefficient by light interferometry

  

  • Online:2011-10-25 Published:2011-10-20

Abstract: Expansion quantity at high temperature is transferred to room temperature by quartz staff,and additive effect deriving from transformation is eliminated by confirming standard.A self-restraint apparatus is made to measure the thermal expansion coefficient,and measuring principle is based on the measuring the micro-displacement by Michelson interferometer;the relative error only is 1.0%,moreover,the measuring process is simple.

Key words: thermal expansion coefficient, interferometer, measurement

CLC Number: 

  • O436.1